Alexa.ThermostatController.Configuration directive to your smart home add-on and you can’t handle it successfully, respond with an Alexa.ThermostatController.Configuration.ErrorResponse event. For details, see Alexa.ThermostatController.Configuration.
ErrorResponse event
In the payload for theAlexa.ThermostatController.Configuration.ErrorResponse, specify the type of the error and include a message with information about the error. For the list of Alexa.ThermostatController.Configuration error types, see Error type values. You can send the error response in a synchronous or asynchronous response. For more details, see Alexa.ErrorResponse.
ErrorResponse event parameters
| Field | Description | Type | Required |
|---|---|---|---|
type | The type of error. Alexa shares this with the customer. | String | Yes |
message | The error message for the error. Alexa doesn’t share this with the customer. | String | Yes |
ErrorResponse event example
Error type values
The following table shows the validAlexa.ThermostatController.Configuration error types.
| Error Type | Description |
|---|---|
CONFIGURATION_UPDATE_NOT_ALLOWED | Configuration changes aren’t allowed by the thermostat device. To accept configuration changes, the customer must interact with the device directly. |
MISSING_SETUP_INFORMATION | Required information for setup is missing from the directive. |
INVALID_TARGET_STATE | The target state isn’t support by the device. |
INVALID_TEMPERATURE_SCALE | The temperature scale isn’t support by the device. |
INVALID_TERMINAL_CONNECTION | One or more terminal connections are invalid. |
INVALID_SYSTEM_TYPE | The HVAC system type isn’t support by the device. |
HEATING_STAGES_EXCEEDS_LIMIT | The number of heating stages exceeds the limit. Include a [validRange](../device-apis/alexa-errorresponse.html#valid-range) object in the payload to indicate the acceptable range. |
COOLING_STAGES_EXCEEDS_LIMIT | The number of cooling stages exceeds the limit. Include a [validRange](../device-apis/alexa-errorresponse.html#valid-range) object in the payload to indicate the acceptable range. |
INVALID_AUXILIARY_HEATING_SYSTEM_TYPE | The specified auxiliary heating system isn’t support by the device. |
COOLING_LOCKOUT_TEMPERATURE_VALUE_OUT_OF_RANGE | The cooling lockout temperature is outside the accepted range. Include a [validRange](../device-apis/alexa-errorresponse.html#valid-range) object in the payload to indicate the acceptable range. |
HEATING_LOCKOUT_TEMPERATURE_VALUE_OUT_OF_RANGE | The heating lockout temperature is outside the accepted range. Include a [validRange](../device-apis/alexa-errorresponse.html#valid-range) object in the payload to indicate the acceptable range. |
Alexa.ThermostatController.Configuration.ErrorResponse error types, you can also use Alexa error types, such as ALREADY_IN_OPERATION. For details, see Alexa.ErrorResponse error type values.
Alexa.ThermostatController.Configuration.ErrorResponse examples
The following examples show the payload for different error types.INVALID_TERMINAL_CONNECTION
The following is an example error response for theINVALID_TERMINAL_CONNECTION error type.
CONFIGURATION_UPDATE_NOT_ALLOWED
The following is an example error response for theCONFIGURATION_UPDATE_NOT_ALLOWED error type.
COOLING_LOCKOUT_TEMPERATURE_VALUE_OUT_OF_RANGE
The following is an example error response for theCOOLING_LOCKOUT_TEMPERATURE_VALUE_OUT_OF_RANGE error type. Include a validRange object in the payload to specify the minimum and maximum acceptable temperatures. The minimum and maximum values contain Temperature objects.